Skip to content
(02) 4646 1660 Contact

Hychem TL9 — Novolac epoxy lining

Product description

HYCHEM TL9 is an epoxyy coating with excellent chemical resistance to a wide range of chemicals varying from mineral acids to hydrocarbons, caustic solutions and aqueous salts. AREAS OF USE The product is designed for use in a wide variety of industries where chemical spillage is commonplace as well as fluid containment in the water industry, power generation, pulp and paper, waste treatment etc. A primary use for HYCHEM TL9 is in the fertilizer industry, mineral processing and ammonium nitrate storage depots. The product is ideal for secondary containment of chemical storage of a large range of chemicals, especially strong caustic soda and concentrated sulphuric acid. It is not recommended for protection against strong organic acid solutions. HYCHEM TL9 whilst primarily designated for use with concrete structures is also suited to the protection of steel requiring protection against corrosive chemicals.

Typical applications

  • FOOD & BEVERAGE PROCESSING
  • MINING
  • MANUFACTURING
  • CHEMICAL STORAGE AREAS
  • SECONDARY CONTAINMENT
  • BATTERY STORAGE
  • METAL PLATING

Application guidelines

Summary from the data sheet — follow the PDF on site.

Surface preparation

Concrete

All concrete surfaces should be clean and free from contaminants such as curing agents and other coatings. Water content of the concrete should be such that it passes the plastic sheet test (ASTM D4263). The resultant surface to be coated must have a minimum surface tensile strength (ASTM 4541) of 2.1 MPa.

  • Prepare the concrete surface by Abrasive Grit Blasting, Shot Blasting, Scarifying, Ultra High Pressure Water Jetting or Scabbling to provide the appropriate surface profile for optimum mechanical keying.
  • The extent of surface preparation required is dependant upon but not limited to the thickness of the coating system to be applied. It is highly recommended surface prepation is carried out in accordance with industry standards and publications such as NACE 02203 item No. 22420 or ICRI Technical Guideline No. 03732.

Steel

All steel surfaces need to be abrasive blast cleaned to a surface profile of a minimum of 75 microns and then coated with HYCHEM Metal Primer .

HYCHEM TL9 is an epoxyy coating with excellent chemical resistance to a wide range of chemicals varying from mineral acids to hydrocarbons, caustic solutions and aqueous salts.

It has been specifically formulated for resistance to 98% sulphuric acid but is also suited to 30% hydrochloric, 40% phosphoric and 20% nitric acid solutions.

ISSUE 100213

Priming

Apply a priming coat of E500P to the substrate. See E500P data sheet for details.

Mixing

Important – Do not mix more than can be adequately applied within 10 to 15 minutes

  • Mix Hychem TL9 liquid components (Resin & Hardener) together using a helical mixer at a speed of 500 rpm until the mix becomes homogeneous (approx. 2 minutes)
  • Move the mixer around from side to side and top to bottom and scrap the sides of the mixing vessel to ensure thorough mixing.
Smooth finish
  • Apply First Coat of Hychem TL9 using a short nap roller at a coverage rate of approx. 4 sqm/litre. Apply Second Coat of Hychem TL9 at a coverage rate of approx. 4 sqm/litre.
Non-slip finish
  • Apply as above. Broadcast grit aggregate (size to suit anti-slip requirement) into the First Coat while it is still wet and allow to cure overnight.
  • Sweep off loose quartz aggregate.
  • Apply second coat of Hychem TL9 to seal the surface.

Slip Resistance is dependent on the size (grading) of aggregates used:

60 mesh Alumina —— R 11 36 mesh Alumina —— R 12 24 mesh Alumina —— R 13

Colour

Hychem TL9 is supplied in grey. The the product is not colour stable under exposure to UV light.

Heavy Duty Option

Hychem E900 may be used as a base layer to form a heavy duty coating providing greater protection from physical and chemical damage. See E900 data sheet for details.

Coverage

When applied at 4 sqm/litre, an 8 litre kit will cover approximateley 32 sqm.

Clean up

Xylene or MEK can be used for cleaning tools and equipment before the mixed compound begins to harden.

Packaging

8 litre & 80 litre kits

Field support

Field support where provided, does not constitute supervisory responsibility. Suggestions made by HYCHEM either verbally or in writing may be followed, modified or rejected by the owner, engineer or contractor since they and not HYCHEM are responsible for carrying out procedures appropriate to a specific application.

Customer responsibility

The technical information and application advice given in this publication is based on the best information available at the time of print. As the information herein is of a general nature, no assumption can be made as to the product suitability for a particular use or application and no warranty as to its accuracy, reliability or completeness either expressed or implied is given other than those required by Commonwealth or State Legislation.

The owner, his representative or the contractor is responsible for checking the suitability of products for their intended use.

ISSUE 100213

Curing conditions

To minimise an unsatisfactory cure the following indicative application conditions should be observed with respect to temperature and humidity levels.

  • 21° C and less than 85% humidity
  • 10° C and less than 75% humidity

Technical data

Technical data for Hychem TL9
PropertyValueUnit / method
Product type100% solids, epoxy novolac
Mix ratio3 volumes resin to 1 volume hardener
Compressive strength65MPa
Tensile strength20MPa
Elongation10%
Flexural strength35MPa
Hardness Shore D70
Pot life60 min@10°C 30 min@ 20°C 15 min@30°C
Cure time24hours
Chemical exposure7days
Application temperatureMin 10°C – Max 32°C
Recoat timeMin 6 hours@25°C Max 24 hours@25°C

From the technical data sheet, updated .

Chemical resistance

Immersion resistance@7 days % Wt change Comment
Water 0.2% Excellent
98% Sulphuric acid -1.5% Very good
25% Sulphuric 0.2% Excellent
30% Nitric acid 1.0 % Good
30% Hydrochloric 0.5% Very good
50% Caustic soda 0.1% Excellent
100% Xylene 0.3% Excellent
Aliphatic hydrocarbons 0.1% Excellent
100% Methylated spirit 8.0 % Short term only
25% Ammonia 0.6 % Excellent
25% Acetic acid 6.5% Short term only
16% Sodium hypochlorite 0.9% Excellent
  • Resistant
  • Spills or short contact

Questions about Hychem TL9

Where is Hychem TL9 used?

Hychem TL9 is used for: Food & beverage processing; Mining; Manufacturing; Chemical storage areas; Secondary containment; Battery storage. See Chemical bund and containment linings.

How long does Hychem TL9 take to cure?

Cure time: 24 hours. Recoat time: Min 6 hours@25°C Max 24 hours@25°C. Lower temperatures extend these times; the data sheet gives the conditions.

Where is the Hychem TL9 data sheet?

Download the Hychem TL9 technical data sheet (PDF), edition 10 February 2013. For the safety data sheet, request it and we send it the same day.

Who installs Hychem TL9?

Hychem TL9 is supplied by Hychem and laid by an approved applicator from our national network — jobs of any size, in every state. How supply and installation works.

Similar systems

Other Concrete Sealers and Coatings systems for chemical containment.

All Concrete Sealers and Coatings