Pharmaceutical and cleanroom flooring
Pharmaceutical plants and cleanrooms need a seamless, impervious floor that does not shed and stands up to repeated cleaning and disinfection. Specify a self-levelling epoxy such as Hychem SL20 (2–4 mm, 95 MPa) or water-based WE500 where low odour matters, and Hychem 177ESD where static must be controlled.
What the floor has to handle
- Cleaning
- repeated cleaning and disinfection
- Surface
- smooth, impervious, unbroken — no joints to shed or harbour particles
- Chemicals
- dilute acids and alkalis, solvents, cleaning agents
- Static
- ESD control where electronics or powders are handled
- Occupancy
- low-odour, low-VOC products for live facilities
- Heavy Duty Industrial SolutionsHychem E300SLEpoxy binder for epoxy floor toppingsView system Data sheetChemical resistant
- Heavy Duty Industrial SolutionsHychem SL20Premium, self-levelling epoxy toppingView system Data sheetChemical resistant
- Concrete Sealers and CoatingsHychem E100Solvent-based, two-component epoxy primer for concreteView system Data sheet
- Concrete Sealers and CoatingsHychem SupaFloorMulti-Purpose Pigmented Epoxy Flooring SystemView system Data sheetChemical resistant
Also suits every industry
Standards that apply
| Standard | Title | What it means for the floor |
|---|---|---|
| PIC/S PE009-17 | Guide to Good Manufacturing Practice for medicinal products (incl. Annex 1) | Adopted by the TGA from 1 September 2025. Cleanroom surfaces must be smooth, impervious and unbroken, and stand up to repeated cleaning and disinfection. |
| ISO 14644-1:2015 | Cleanrooms — Classification of air cleanliness by particle concentration | Classifies the room's air, not the floor. A seamless, non-dusting floor helps the room hold its class. |
| IEC 61340-5-1 | Protection of electronic devices from electrostatic phenomena — General requirements | The ESD control programme for an electronics area; the floor is one element of it, with footwear and grounding. |
Which product holds which certificate: certifications and approvals.
FAQs about pharmaceutical and cleanroom flooring
Is there a GMP-certified floor?
GMP applies to the facility and how it is run, not to a floor product. Choose a floor that meets the surface requirements — smooth, impervious, cleanable — and keep its data sheet and chemical-resistance table in the validation file.
Can a floor be ISO 14644 compliant?
ISO 14644-1 classifies the room’s air. A seamless, non-dusting floor helps the room hold its class; the floor itself is not certified to it.
Which epoxy for a laboratory?
SL20 for a hard, smooth, chemical-resistant floor; WE500 where low odour and low VOC matter in an occupied building.
Specification service
Specifying for this environment?
Tell us the floor, what happens on it and when it needs to be down.
or call 1300 HYCHEM