Polyac 12 — Fast-curing PMMA primer for mineral surfaces
Product description
POLYAC® 12 is a rigid, very fast curing, PMMA (Polymethyl methacrylate) based primer for the POLYAC® systems, to be applied on mineral surfaces.
Typical applications
- POLYAC® 12 is a rigid primer for the POLYAC® floor, membrane and ther POLYAC® systems that are applied to mineral, absorbent surfaces such as sand/cement screeds, concrete, brick, tiles, … The primer has excellent adhesion and can be applied at temperatures below freezing thanks to its rapid reaction and good reactivity. POLYAC® 12 can be used as concrete protection and the sanded-in variant can be used as a fast primer for epoxy and polyurethane floor systems.
Features and benefits
- High reactivity
- Fast curing
- Applicable at low temperature
- Optimal viscosity
- Widely applicable
- Can be applied horizontally and vertically
- Optimized polymerization under difficult conditions
- To be applied with roller or brush.
Approvals and certifications
- ISO 9001:2015 quality management (BSI, FM 78518)
- ISO 14001:2015 environmental management (BSI, EMS 716699)
- REACH compliant
- Complies with Belgian VOC emission legislation
- A+ indoor air emissions class
Application guidelines
Summary from the data sheet — follow the PDF on site.
Application
Note: The following is a typical application description. In case of other jobsite parameters, please contact our technical department.
POLYAC® 12 is evenly distributed with a spatula or rubber squeegee and a short-haired paint roller. Apply enough primer to create a tight coat with full coverage. Apply a second coat of POLYAC® 12 on highly porous surfaces. Extra mechanical adhesion can be obtained by broadcasting dry quartz into the layer that has not yet cured (0,5 kg/m2 ). Polyurethane and epoxy systems can only be applied on a broadcasted POLYAC® 12 primer. Note: Do not disturb the paraffin layer that occurs during curing.
- POLYAC® 12
- RIGID, VERY FAST CURING, PMMA BASED PRIMER FOR
Preliminary analyses
Before starting the substrate preparation and applying the products, it is important to test various parameters in order to achieve a good and sustainable result.
Compressive strength of the substrate: min. 25 N/mm2.
Tensile strength of the substrate: min. 1,5 N/mm².
POLYAC® 12 must be applied on a dry surface. Moisture content in the substrate: ≤ 5% moisture.
Conditions during the application and curing: see “implementation conditions” further described in this technical data sheet.
Technically studied dilatation joints must be provided. These are resumed in the synthetic resin system to be installed.
The flatness of the surface must be consistent with the desired requirements. Should this not be the case, correct measures must be taken to fill in or smooth out the unevenness with products that are complementary to the substrate and to the synthetic resin system to be installed.
Shrink joints and passive cracks can be coated. This on condition that they are not used as dilatation joints or if they do not follow other movements of the structure and the substrate and that they are flattened with products that are complementary to the substrate and to the synthetic resin system to be installed.
Required tools
Mixer with spindle (min. 300 rpm)
Spatula or rubber squeege.
Brush or paint roller suitable for synthetic resin-based products.
Masking tape.
Preparation of the substrate
- Cracks, joints and other parts that show water leaks must first be made completely water-tight and leak-proof.
- The surface must be mechanically pre-treated. This can be achieved by removing the dust by bullet- or sandblasting or by grinding the surface.
- Tiles are to be degreased well and grinded with a diamond blade. These treatments ensure that an open texture surface is obtained, to remove the cement skin from concrete and old remnants of coatings and adhesives.
- High pressure water jetting is possible but then the surface must dry sufficiently (moisture content in the substrate: ≤ 5% moisture) before applying the primer.
- Always apply the products on a clean surface, free from adhesion reducing materials such as dirt, oil, grease, old coatings or surface treatments, …
- The parts of the surfaces to be coated that do not meet the requirements as described above (compressive strength, tensile strength, parts that are not well connected, …) must be treated or removed and repaired according to a correct method and with products that are complementary to the substrate and the synthetic resin system to be installed. Remove any loose parts by brushing properly and remove dust with an industrial vacuum cleaner.
Mixing
Mix POLYAC® 12 well before use. Paraffin can separate during storage.
Dispense an amount of resin that can be processed within 15 minutes.
Add 1 to 5% curing powder. POLYAC® CATALYST must be ordered separately.
| Temp. | In % | POLYAC® CATALYST per 1kg POLYAC® 12 |
|---|---|---|
| 0°C | 5% | 50g |
| 5°C | 4% | 40g |
| 10°C | 3% | 30g |
| 20°C | 2% | 20g |
| 30°C | 1% | 10g |
Mix until the powder is completely dissolved.
Preparation of the equipment
Always work with clean mixing containers and application material.
Polyac® systems
2C
Finishing
The cured primer can be overcoated after one hour (+20°C) with the POLYAC® system to be installed.
Application conditions
Conditions during the application and curing of the products.
Concrete should be at least 28 days old.
The recommended processing temperature for substrate, environment, material and products is between +5°C and +35°C. For temperatures lower than +5°C please contact RESIPLAST NV.
Relative humidity: Max. 85%
Dew point: The temperature of the substrate and of the not fully cured product must be at least 3°C higher than the dew point. Avoid condensation on the surface from the moment that the preparations start until the complete curing of the products. Ensure adequate ventilation and a low relative humidity during curing.
Cleaning and maintenance
Clean the used tools with SOLVENT MEK or ethyl acetate before the curing of POLYAC® 12. Cured products residues must be removed mechanically.
For the cleaning and maintenance of the installed synthetic resin system, please refer to the information leaflets:
- Cleaning and maintenance of synthetic resin floor systems – INDUSTRY
- Cleaning and maintenance of synthetic resin floor systems – PUBLIC
AND PRIVATE BUILDINGS.
Complimentary products
- Cleaning solvent for tools: SOLVENT MEK or ethyl acetate
Advice / focal points
POLYAC® 12 as primer on contaminated surfaces:
First perform an adhesion and hardening test.
After the substrate preparation, take a small amount of POLYAC® 12.
Add 3% of POLYAC® CATALYST. Mix until the powder is completely dissolved. Pour the mixture in a large layer over the surface and let it cure completely. Test the adhesion by separating the primer from the surface with a hammer and chisel. With a sticky or poorly adhering contact surface, the substrate must be further cleaned or an alternative primer must be selected.
Consumption
Consumption: 0.35 kg/m²
For porous surfaces the consumption is higher.
Packaging
| 20 kg | Metal pail |
|---|---|
| 180 kg | Drum |
| 0,5 kg | Plastic pail |
|---|---|
| 5 kg | Plastic pail |
| 25 kg | Box |
Storage and shelf life
Store POLYAC® products in a dry, well-ventilated storage area between +5 and +35°C.
Shelf life: 12 months after production date.
In case of doubt, please contact RESIPLAST NV and state the batch number on the packaging. Do not discharge into groundwater, surface water of sewers. Dispose of contaminated packaging and residues in accordance with the applicable legal requirements.
Safety precautions
Please read the safety data sheets carefully before using POLYAC® products. The products emit a characteristic odour during processing. Provide adequate ventilation. Keep away from sources of ignition. No smoking. Avoid skin contact. Eye irritation and/or hypersensitivity may occur at high vapour concentrations, upon inhalation and/or skin contact. Do not store food or beverages in the work area. Always wear personal protective equipment in accordance with all applicable local regulations and legislation. Gloves and safety goggles are mandatory.
Test conditions
All values on this technical sheet are average values that result from tests carried out under laboratory conditions (20°C and 50% RH). Values that are measured on the construction site may show a slight deviation since the environmental conditions, the application, and the way of processing our products are beyond our control. Do not add any products other than those indicated on the technical documentation.
Technical data
| Property | Value | Unit / method |
|---|---|---|
| APPEARANCE – COMPOSITION | Liquid with low viscosity, colourless, slightly cloudy. | |
| REACTION TIMES | Processing time after mixing: 10 to 15 min. Walkable: after 1 hour Recoatable: after 1 hour Fully mechanical load: after 2 hours Full chemical resistance: after 2 hours Times measured at 20°C; lower temperatures extend the curing time. | |
| Odour | Methyl methacrylate (See also information sheet “POLYAC® ODOUR”) | |
| POLYAC® CATALYST | BPO 50%, depending on the temperature from 1% to 5 weight% calculated on the proportion of POLYAC® 12 | |
| Viscosity | 200 – 250 mPa.s (20°C Brookfield, spindle III/200 rpm) | |
| Density | 1 g/cm³ ±0,1 (20°C) | |
| Flash point | 10°C (MMA, DIN 51 755) | |
| Exothermic peak | 120 – 145 | °C |
| POLYAC® 12 + 2% POLYAC® CATALYST | ||
| Density | 0.98 kg/dm³ | |
| Colour | Yellow-brown transparent | |
| Shore D hardness | 70 – 80 |
Chemical resistance
Polymerized POLYAC® resins have good chemical resistance to alkalis, petroleum derivatives, acid, salts and maintenance products. POLYAC® resins are not resistant to solvents. For more information please contact RESIPLAST NV.
Questions about Polyac 12
How long does Polyac 12 take to cure?
Reaction times: Processing time after mixing: 10 to 15 min. Walkable: after 1 hour Recoatable: after 1 hour Fully mechanical load: after 2 hours Full chemical resistance: after 2 hours Times measured at 20°C; lower temperatures extend the curing time.
Which standards and approvals does Polyac 12 meet?
ISO 9001:2015 quality management (BSI, FM 78518); ISO 14001:2015 environmental management (BSI, EMS 716699); REACH compliant; Complies with Belgian VOC emission legislation; A+ indoor air emissions class.
Where is the Polyac 12 data sheet?
Download the Polyac 12 technical data sheet (PDF). For the safety data sheet, request it and we send it the same day.
Who installs Polyac 12?
Polyac 12 is supplied by Hychem and laid by an approved applicator from our national network — jobs of any size, in every state. How supply and installation works.
Similar systems
Other Heavy Duty Industrial Solutions systems.
- Polyac 62Hard, liquid-tight top layer for Polyac floor systemsView system Data sheetChemical resistantFast cure
- Polyac 18Fast-curing PMMA primer for damp mineral surfaces and new concreteView system Data sheetFast cure
- Polyac 55Fast-curing PUMA binder for self-levelling, levelling and wear layers, 1–5 mmView system Data sheetFast cureSlip resistant