Skip to content
(02) 4646 1660 Contact

Polyac 18 — Fast-curing PMMA primer for damp mineral surfaces and new concrete

Product description

POLYAC® 18 is a rigid, very fast curing, PMMA (Polymethyl methacrylate) based primer for the POLYAC® systems, to be applied on damp mineral surfaces or on new concrete.

Typical applications

  • POLYAC® 18 is a rigid primer for the POLYAC® floor, membrane and ther POLYAC® systems that are applied to damp mineral, absorbent surfaces such as sand/cement screeds, concrete, brick, tiles, … The primer has excellent adhesion and can be applied a temperatures below freezing thanks to its rapid reaction and good reactivity.

Features and benefits

  • On damp surfaces
  • High reactivity
  • Fast curing
  • Applicable at low temperature
  • Optimal viscosity
  • Widely applicable
  • Can be applied horizontally and vertically
  • Optimized polymerization under difficult conditions
  • Can be applied with roller or brush

Approvals and certifications

  • ISO 9001:2015 quality management (BSI, FM 78518)
  • ISO 14001:2015 environmental management (BSI, EMS 716699)
  • REACH compliant
  • Complies with Belgian VOC emission legislation
  • A+ indoor air emissions class

Application guidelines

Summary from the data sheet — follow the PDF on site.

Application

Note: The following is a typical application description. In case of other jobsite parameters, please contact our technical department.

POLYAC® 18 is evenly distributed with a rubber squeege or a short-haired paint roller. Apply enough primer to create a tight coat with full coverage. Apply a second coat of POLYAC® 18 on highly porous surfaces. Extra mechanical adhesion can be obtained by broadcasting dry filter sand into the layer that has not yet cured (0,5 kg/m2).

Polyurethane and epoxy systems can only be applied on a broadcasted

POLYAC® 18 primer. Note: Do not disturb the paraffin layer that occurs during curing.

RIGID, VERY FAST CURING, PMMA-BASED PRIMER FOR POLYAC®

SYSTEMS, TO BE APPLIED ON DAMP MINERAL SURFACES.

POLYAC® 18 2C

Preliminary analyses

Before starting the substrate preparation and applying the products, it is important to test various parameters in order to achieve a good and sustainable result.

  • Compressive strength of the substrate: min. 25 N/mm2
  • Tensile strength of the substrate: min. 1,5 N/mm²

Visible water present on the surface is not allowed. Moisture content in the substrate: ≤ 10% moisture.

Conditions during the application and curing: see “Application conditions” further described in this technical data sheet.

Technically studied dilatation joints must be provided.

These are resumed in the synthetic resin system to be installed.

The flatness of the surface must be consistent with the desired requirements. Should this not be the case, correct measures must be taken to fill in or smooth out the unevenness with products that are complementary to the substrate and to the synthetic resin system to be installed.

Shrink joints and passive cracks can be coated. This on condition that they are not used as dilatation joints or if they do not follow other movements of the structure and the substrate and that they are flattened with products that are complementary to the substrate and to the synthetic resin system to be installed.

Required tools
  • Mixer with spindle (min. 300 rpm)
  • Divider-wiper

Brush or pain roller suitable for synthetic resin-based products.

Masking tape.

Preparation of the substrate
  • Cracks, joints and other parts that show water leaks must first be made completely water-tight and leak-proof.
  • The surface must be mechanically pre-treated. this can be achieved by removing the dust by bullet- or sandblasting or by sanding the surface.
  • Tiles are to be degreased well and sanded with a diamond blade.
  • These treatments ensure that an open texture surface is obtained, to remove the cement skin from concrete and old remnants of coatings and adhesives.

High pressure water jetting is possible but then the surface must dry sufficiently before applying the primer. Visible water present on the surface is not allowed. (Moisture content in the substrate: ≤ 10% moisture)

Always apply the products on a clean surface, free from adhesion reducing materials such as dirt, oil, grease, old coatings or surface treatments, …

The parts of the surfaces to be coated that do not meet the requirements as described above (compressive strength, tensile strength, parts that are not well connected, …) must be treated or removed and repaired according to a correct method and with products that are complementary to the substrate and the synthetic resin system to be installed. Remove any loose parts by brushing properly and remove dust with an industrial vacuum cleaner.

Mixing

Mix POLYAC® 18 well before use. Paraffin can separate during storage.

Dispense an amount of resin that can be processed within 15 minutes.

Add 1 to 5% curing powder. POLYAC® CATALYST must be ordered separately.

Add POLYAC® CATALYST to POLYAC® 18
Temp. In % POLYAC® CATALYST per 1kg POLYAC® 18
0°C 5% 50 g
5°C 4% 40 g
10°C 3% 30 g
20°C 2% 20 g
30°C 1% 10 g

Mix until the powder is completely dissolved.

Preparation of the equipment

Always work with clean mixing containers and application material.

Finishing

The cured primer layer can be overcoated after one hour (+20°C) with the POLYAC® system to be installed.

Application conditions

Conditions during the application and curing of the products.

The recommended processing temperature for substrate, environment, material and products is between +5°C and +35°C. For temperatures lower than +5°C please contact RESIPLAST NV.

Relative humidity: Max. 85%

Dew point: The temperature of the substrate and of the not fully cured product must be at least 3°C higher than the dew point. Avoid condensation on the surface until the products have fully cured. Ensure adequate ventilation and a low relative humidity:during curing.

Cleaning and maintenance

Clean the used tools with SOLVENT MEK or ethyl acetate before the curing of POLYAC® 18. Cured products residues must be removed mechanically.

For the cleaning and maintenance of the installed synthetic resin system, please refer to the information leaflets:

  • Cleaning and maintenance of synthetic resin floor systems – INDUSTRY
  • Cleaning and maintenance of synthetic resin floor systems – PUBLIC

AND PRIVATE BUILDINGS.

Complimentary products
  • Cleaning solvent for tools: SOLVENT MEK or ethyl acetate
Advice / focal points

As primer on a contaminated surface:

First perform an adhesion and hardening test.

After the substrate preparation, take a small amount of POLYAC® 18.

Add 3% of POLYAC® CATALYST. Mix until the powder is completely dissolved. Pour the mixture in a large layer over the surface and let it cure completely. Test the adhesion by separating the primer from the surface with a hammer and chisel. With a sticky or poorly adhering contact surface, the substrate must be further cleaned or an alternative primer must be selected.

Consumption

Consumption: 0.35 kg/m²

For porous surfaces the consumption is higher.

Packaging
POLYAC® 18
20 kg Metal pail
180 kg Drum

To be ordered separately:

Polyac® catalyst
0,5 kg Plastic pail
5 kg Plastic pail
25 kg Box
Storage and shelf life

Store POLYAC® products in a dry, well-ventilated storage area between +5 and +35°C. Shelf life: 12 months after production date.

In case of doubt, please contact RESIPLAST NV and state the batch number on the packaging. Do not discharge into groundwater, surface water of sewers. Dispose of contaminated packaging and residues in accordance with the applicable legal requirements.

Safety precautions

Carefully read the safety data sheets before using POLYAC® products. A characteristic odour arises during processing. Ensure adequate ventilation, keep away from sources of ignition and do not smoke. Avoid skin contact. Eye irritation and/or hypersensitivity may occur with severe vapour concentration, inhalation and/or skin contact. Do not store food (food, drinks) in the same workspace. Always wear personal safety equipment in accordance with the applicable local guidelines and legislation. Gloves and safety glases are mandatory.

Test conditions

All values on this technical sheet are average values that result from tests carried out under laboratory conditions (20°C and 50% RH). Values that are measured on the construction site may show a slight deviation since the environmental conditions, the application, and the way of processing our products are beyond our control. Do not add any products other than those indicated on the technical documentation.

Technical data

Technical data for Polyac 18
PropertyValueUnit / method
APPEARANCE – COMPOSITIONLiquid with low viscosity, colourless, slightly cloudy.
REACTION TIMESProcessing time after mixing: 10 to 15 min. Trafficable: after 1 hour Recoatable: after 1 hour Fully mechanical load: after 2 hour Full chemical resistance: after 2 hour Times measured at 20°C; lower temperatures extend the curing time.
OdourMethyl methacrylate (See also information sheet “POLYAC® ODOUR”)
POLYAC® CATALYSTBPO 50%, depending on the temperature from 1% to 5 weight% calculated on the proportion of POLYAC® 18
Viscosity200 – 250 mPa.s (20°C Brookfield, spindle III/200 rpm)
Density1 g/cm³ ±0,1 (20°C)
Flash point10°C (MMA, DIN 51 755)
Exothermic peak120 – 145°C
POLYAC® 18 + 2% POLYAC® CATALYST
Density0.98 kg/dm³
ColourYellow-brown transparent
Shore D hardness70 – 80

Chemical resistance

Polymerized POLYAC® resins have good chemical resistance to alkalis, petroleum derivatives, acid, salts and maintenance products.For more information please contact RESIPLAST NV.

Questions about Polyac 18

How long does Polyac 18 take to cure?

Reaction times: Processing time after mixing: 10 to 15 min. Trafficable: after 1 hour Recoatable: after 1 hour Fully mechanical load: after 2 hour Full chemical resistance: after 2 hour Times measured at 20°C; lower temperatures extend the curing time.

Which standards and approvals does Polyac 18 meet?

ISO 9001:2015 quality management (BSI, FM 78518); ISO 14001:2015 environmental management (BSI, EMS 716699); REACH compliant; Complies with Belgian VOC emission legislation; A+ indoor air emissions class.

Where is the Polyac 18 data sheet?

Download the Polyac 18 technical data sheet (PDF). For the safety data sheet, request it and we send it the same day.

Who installs Polyac 18?

Polyac 18 is supplied by Hychem and laid by an approved applicator from our national network — jobs of any size, in every state. How supply and installation works.

Similar systems

Other Heavy Duty Industrial Solutions systems.

All Heavy Duty Industrial Solutions