Hychem Hycrete PU-TC Solar — High-build coloured polyurethane coating with improved UV resistance
Product description
Hychem HYCRETE PU-TC-SOLAR is a 3-component, high build coloured polyurethane coating. It has excellent mechanical and chemical properties. It is resistant to organic acids, dilute mineral acids, vegetable and animal fats, petroleum oils and solvents. HYCRETE PU-TC-SOLAR is an ultra-low yellowing UV stable semi-gloss top coat. PU-TC-SOLAR
Typical applications
- HYCRETE PU-TC-SOLAR is used as a protective coating in situations subject to constant exposure to aggressive chemicals, and mechanical abuses such as dairy, food and beverage production facilities, warehouse and distribution centres, chemical and minerals processing plants and waste treatment plants. Hycrete TC Solar is typically applied as a final coat over Hycrete SL or Hycrete TC.
- Please read these data sheets for recommended application of each product.
- PRODUCT CHARACTERISTICS (A) Technical data
- Liquid mixture (A+B+C) 1. Solids content 99% 2. Density (25°C) 1.34 g/cm3 3. Viscosity (25°C) A+B: 1000–1500 mPa’s 4. Packaging size (3-component + pigment pack) 3.3 kg (+0.175 kg colour paste) (1 kg A + 1.3 kg B + 1 kg C + 0.175 kg colour paste) 5. Shelf life 9 months in closed original container 6. Storage Dry at 10–30°C, avoid direct sunlight (B) Technical data
- Cured material 1. Adhesive strength (DIN ISO 4624) <1.5 N/mm2 (concrete failure) 2. Hardness (DIN EN ISO 868)
- Shore D52 after 7 days
- Shore D60 after 28 days
Features and benefits
- Excellent chemical resistance – resists organic acids, dilute mineral acids, vegetable and animal fats, petroleum ils and solvents.
- High impact/abrasion resistance – resists mechanical wear and heavy vehicular traffic.
- Semi-gloss finish – easy to keep clean and maintain.
- Odourless – non-tainting to food.
- Solvent free – Very low VOC non-flammable.
- Improved UV resistance compared to conventional
Application guidelines
Summary from the data sheet — follow the PDF on site.
Application
Surface preparation on concrete
Prior to the application of HYCRETE PU-TC-SOLAR, the substrate must be thoroughly prepared.
- The concrete substrate must be firm, clean and dry with a minimum compressive strength of 25 MPa and a minimum surface tensile strength of 1.5 MPa.
- New concrete must be allowed to cure for a minimum of 28 days.
- Remove all surface laitance, contaminants, existing coatings, curing compounds and any weak or loose materials.
- Prepare the concrete surface by Grinding, Shot Blasting, Scarifying, Ultra High-Pressure Water Jetting or Scabbling to provide the appropriate concrete surface profile (CSP) for optimum mechanical keying.
- The extent of surface preparation required is dependent upon but not limited to the thickness of the coating system to be applied. It is highly recommended that all surface preparation is carried out in accordance with industry standards and publications such as NACE 02203 item No. 22420 or ICRI Technical Guideline No. 03732.
Curing and Accelerating
Hycrete TC Solar is by nature relatively slow curing, it is therefore recommended to add 20ml AC20 per kit where temperatures are below 20°C.
10ml AC20 may also be added at temperatures 20-30°C for quicker curing.
Do not apply over damp or wet surfaces.
Do not apply where there is water vapour transmission.
(C) Technical data
- Mixing ratio A : B : C : CP 1 : 1.3 : 1 : 0.175 by weight (kg)
- Working time (25°C) Approx. 20–25 minutes
- Application temperature 10–30°C (min. 3°C above dew point)
- Material consumption approximately 0.15–0.5 kg/m2
- Cure time 20°C to withstand:
- Foot traffic
- Heavy traffic
Exposure to chemical note: with AC20.
48 hours after 4 days after 7 days
Mixing
Mix components A and B together for 30 seconds. Add aggregate bag and mix until a smooth consistency without lumps is achieved, 1–2 minutes should be sufficient. If using AC20 add and mix for 30 seconds.
Hychem HYCRETE PU-TC-SOLAR is a 3-component, high build coloured polyurethane coating. It has excellent mechanical and chemical properties. It is resistant to organic acids, dilute mineral acids, vegetable and animal fats, petroleum oils and solvents. HYCRETE PU-TC-SOLAR is an ultra-low yellowing UV stable semi-gloss top coat.
Overcoating
Overcoating: within 24 hours of the previous coat of Hycrete Solar.
Refer technical data sheet curing of other products if Hycrete TC
Solar is applied over another product.
Coverage
The following information is a guide only.
Over a smooth surface the expected coverage is about 8–10 m²/litre. When applied over a broadcast surface the consumption will depend on the profile, however, approximately 3-5 m²/litre can be expected.
Packaging
HYCRETE PU-TC-SOLAR is a 3-component neutral product consisting of a resin, hardener and blended fillers. A pigment pack needs to be added for colour.
Component breakdown:
- Part A – 1 kg
- Part B – 1.3 kg
- Part C – Aggregate 1 kg + 0.175 kg pigment
The mixed product will yield approximately 2.5 litres.
Safety precautions
Wear gloves, eye protection, masks and overalls during mixing and application.
Technical data
| Property | Value | Unit / method |
|---|---|---|
| Packaging size (3-component + pigment pack) | 3.3 kg (+0.175 kg colour paste) (1 kg A + 1.3 kg B + 1 kg C + 0.175 kg colour paste) | |
| Shelf life | 9 months in closed original container | |
| Storage | Dry at 10–30°C, avoid direct sunlight |
From the technical data sheet, updated .
Physical properties
| Property | Value | Unit / method |
|---|---|---|
| Adhesive strength (DIN ISO 4624) | <1.5 N/mm2 (concrete failure) | |
| Hardness (DIN EN ISO 868) | Shore D52 after 7 days Shore D60 after 28 days |
From the technical data sheet, updated .
Questions about Hychem Hycrete PU-TC Solar
Where is Hychem Hycrete PU-TC Solar used?
Hychem Hycrete PU-TC Solar is used for: Please read these data sheets for recommended application of each product.; PRODUCT CHARACTERISTICS (A) Technical data; Cured material 1. Adhesive strength (DIN ISO 4624) <1.5 N/mm2 (concrete failure) 2. Hardness (DIN EN ISO 868); Shore D52 after 7 days; Shore D60 after 28 days.
Where is the Hychem Hycrete PU-TC Solar data sheet?
Download the Hychem Hycrete PU-TC Solar technical data sheet (PDF), edition 23 August 2021. For the safety data sheet, request it and we send it the same day.
Who installs Hychem Hycrete PU-TC Solar?
Hychem Hycrete PU-TC Solar is supplied by Hychem and laid by an approved applicator from our national network — jobs of any size, in every state. How supply and installation works.
Similar systems
Other Heavy Duty Industrial Solutions systems.
- Hychem Hycrete TCTopcoat for polyurethane concreteView system Data sheetChemical resistantLow temperature cureLow VOC
- Hychem Hycrete PU-SLPolyurethane concrete flooring systemView system Data sheetFast cureFood safeSlip resistant
- Hychem Aero-Tuff RapidEpoxy and polyaspartic floor system for hangars, UV stableView system Data sheetChemical resistantGreen StarSlip resistant