Skip to content
(02) 4646 1660 Contact

Hychem E300 — Epoxy binder and primer for epoxy floor and wall toppings

Product description

HYCHEM E300 is a premium grade, solventless epoxy binder with superior chemical resistance and better quality surface finish than conventional epoxy binders. The product is used to produce a 4–6mm epoxy topping using a spreader box and hand trowelling technique. E300 is also used as a primer system. HYCHEM E300 is recommended for use as a heavy duty floor topping system for the protection of concrete floor surfaces in food manufacturing plants and retail food handling premises. It is particularly suited to floors which require re-levelling with appropriate falls to drains. E300 is commonly used as an effective primer system in the water industry for products including Hychem E500T and TL5.

Typical applications

  • Assembly plants and factories
  • Bakeries
  • Battery rooms and warehouses
  • Commercial kitchens and bars
  • Dairy and cheese processing
  • Food and beverage plants
  • Meat processing establishments
  • Public utilities and sports complexes
  • Concrete water industry assets

Features and benefits

  • High resistance to vegetable and animal fats
  • High resistance to petroleum oils
  • Versatile – suitable for all general purpose use
  • Abrasion and impact resistant – hard wearing and durable
  • Low odour – will not taint food
  • Non-flammable, no fire hazard
  • Excellent resistance to dilute acids and alkalies
  • Excellent trowellability

Application guidelines

Summary from the data sheet — follow the PDF on site.

Surface preparation

Epoxy toppings can exert considerable shear forces on the underlying concrete substrate due to differential thermal movements. It is most important that the concrete surface is adequately prepared. The cement paste layer and any surface coatings already in existence need to be removed. This is best carried out using captive shot blasting, grinding or scarifying.

Prior to the application of E300, the substrate must be thoroughly prepared.

  • The concrete substrate must be firm, clean and dry with a minimum compressive strength of 25 MPa and a minimum surface tensile strength of 1.5 MPa.
  • New concrete must be allowed to cure for a minimum of 28 days.
  • Ensure moisture content of concrete is less than 6%.
  • Remove all surface laitance, contaminants, existing coatings, curing compounds and any weak or loose materials.
  • Prepare the concrete surface by Grinding, Shot Blasting, Scarifying, Ultra High Pressure Water Jetting or Scabbling to provide the appropriate concrete surface profile (CSP) for optimum mechanical keying.
  • The extent of surface preparation required is dependant upon but not limited to the thickness of the coating system to be applied. It is highly recommended that all surface preparation is carried out in accordance with industry standards and publications such as NACE 02203 item No. 22420 or ICRI Technical Guideline No. 03732.

Falls to drains must first be prepared using HYCHEM E300 and a coarse quartz sand mixture.

Mixing
  • In a clean container, mix HYCHEM E300 liquid components (Resin and Hardener @ 2:1) using a helical mixer at a speed of 500 rpm until the mix becomes homogenous (1–2 minutes).
  • Add HYCHEM Quartz trowelling aggregate aggregates at a ratio of 4:1 by volume, gradually to the mix whilst still mixing.
  • Move the mixer around from side to side and top to bottom and scrape the sides of the mixing vessel to ensure thorough mixing.
Application

The epoxy sand mortar is poured onto the floor and spread out at approximately 5–6mm thickness, using a spreader gauge or gauged application box. The surface is then consolidated by hand trowelling and is allowed to cure. A coarser antislip may be incorporated by casting on to the trowelled surface. The cured topping is then surface sealed using the mixed resin containing appropriate pigment. Addition of a little quartz flower helps to provide coating depth.

Pre-conditioning product

It is important to note that even when the application environment is warm, products which have been stored in cold or cooler conditions should always be pre-conditioned ideally to 20–25°C to ease mixing, application and help avoid other potential issues such as amine bloom or blushing.

Applying a cold product in a warm environment is not recommended.

Roller application

  • For priming add the mixed product at approximately 4–7m² depending on surface porosity.
  • To assist workability in certain conditions, a solvent such as Xylene can be added to the mix at a maximum of 10% by volume if necessary. Please note this may affect the pot life and cure times slightly.
  • It is always recommended to mechanical abrade the primer if it is an external application and/or it is recoated several hours after curing. Always remove any contaminants and ensure surface is clean and dry.
Jointing

Joints in the floor need to be reflected in the epoxy topping. When the topping has cured, the surface needs to be sawcut and an epoxy joint sealant such as HYFLEX NS applied.

Clean up

Xylene can be used for cleaning tools and equipment before the mixed compound begins to harden.

Coverage

2 litres of HYCHEM E 300 are required to produce a 5mm epoxy topping.

Packaging

Available in 3, 12, 30, 60 and 600 litre kits.

Shelf life

12 months from date of manufacture, stored under shelter at 25°C in original unopened container.

Safety precautions

Epoxy polymer products may cause allergic reactions through skin contact. Goggles and protective gloves and clothing should be worn at all times. Ensure that there is adequate ventilation and air flow and avoid breathing the vapour.

Physical properties

Physical properties for Hychem E300
PropertyValueUnit / method
Mix ratio–volume2:1 resin to hardener
Specific gravity1.13:1
Pot life40minutes
Tack free time6hours
Re-coat time8–20hours
App. temperature5 to 30°C
Service temperatureUp to 65°C
Compressive strength60 MPa (6:1) quartz mortar

From the technical data sheet, updated .

Chemical resistance

The chemical resistance of a material can be determined by the wt gain of a sample immersed in the chemical. The greater the wt gain, the poorer the resistance of the material. The table below gives the relative resistance of HYCHEM E300 relative to other available epoxy binders. A value of 100 is equivalent to an absorption of 3%.

CHEMICAL GP E300 E300 SL E300SLF TL2 Flash
15% Acetic acid 80 60 60 25 25
20% Caustic soda 0 0 0 0 0
20% Phosphoric acid 25 40 40 60 60
12% Hypochlorite 15 15 15 15 15
Xylene/butanol blend 200 200 125 20 20

Questions about Hychem E300

Where is Hychem E300 used?

Hychem E300 is used for: Assembly plants and factories; Bakeries; Battery rooms and warehouses; Commercial kitchens and bars; Dairy and cheese processing; Food and beverage plants.

How long does Hychem E300 take to cure?

Tack free time: 6 hours. Re-coat time: 8–20 hours. Lower temperatures extend these times; the data sheet gives the conditions.

Where is the Hychem E300 data sheet?

Download the Hychem E300 technical data sheet (PDF), edition 24 February 2017. For the safety data sheet, request it and we send it the same day.

Who installs Hychem E300?

Hychem E300 is supplied by Hychem and laid by an approved applicator from our national network — jobs of any size, in every state. How supply and installation works.

Similar systems

Other Concrete Sealers and Coatings systems.

All Concrete Sealers and Coatings