Hychem Universal — Pre-tinted, 100% solids epoxy coating
Product description
Hychem Universal is a multi-purpose, heavy-duty epoxy coating designed for use in a wide range of industries. Universal is supplied in convenient, pre-tinted kits with an extended pot-life for simple on-site mixing and application. Composed of 100% solids epoxy technology, Universal provides exceptional longevity in high-use environments. Hychem Universal is Low-VOC, Critical Radiant Flux Tested to AS ISO 9239.1 and can be used in conjunction with hard-wearing aggregates to produce a range of slip-resistance ratings in accordance with AS/NZS 4586.
Typical applications
- Hychem Universal is recommended for use as a coloured, heavy-duty floor coating for commercial, industrial and residential applications.
- Garages
- Warehouses
- Schools, hospitals and public buildings
- Prisons
- Retail areas
- Domestic and commercial garages
- Back of house areas
- Stock & Plant rooms
- Workshops
- Pharmaceutical Industry
- Laboratories
- Food and Beverage Industry
Features and benefits
- Convenient pre-tinted kits for ease of application
- Extended pot life
- Available with rapid cure hardener for quick return to service
- Anti-slip applications possible
- High resistance to mineral acids
- High resistance to caustic and salt solutions
- High resistance to petroleum oils
- Versatile
- Abrasion and impact resistant
- High mechanical strength
- Non flammable
- Cures rapidly
- Seamless
- Excellent resistance to early water spotting
Application guidelines
Summary from the data sheet — follow the PDF on site.
Surface preparation
Prior to the application of Hychem Universal, the substrate must be thoroughly prepared.
- The concrete substrate must be firm, clean and dry with a compressive strength of 25 MPa and a minimum surface tensile strength of 1.5 MPa.
- New concrete must be allowed to cure for a minimum of 28 days.
- Remove all surface laitance, contaminants, existing coatings, curing compounds and any weak or loose materials.
- Hychem Universal is a self-priming floor coating. For excessively porous substrates it is recommended to prime with Hychem E100.
Pre-conditioning product
It is important to note that even when the application environment is warm, products which have been stored in cold or cooler conditions should always be pre-conditioned ideally to 20-25°C to ease mixing and application and help avoid other potential issues such as amine bloom or blushing. Applying a cold product in a warm environment is not recommended.
Application
The moisture content of the concrete must be below 6%. Mix only enough material that can be applied within the working time which is temperature dependent.
Roller application
- Mix Part A with Part B in accordance with mixing ratios using a mechanical stirrer until complete uniformity is achieved. This should be achieved in approximately 3 minutes.
- Apply the mixed product at a rate of approximately 6-8m²/litre. If applying over an anti-slip base later where the base has been broadcast with an aggregate, the consumption will increase to approximately 2-3m²/litre but this will obviously vary depending on the size of aggregate used.
- To assist workability under certain conditions Hychem Universal can be diluted using Xylene at a maximum rate of 10% by volume where necessary. Please note this may effect pot life and cure times slightly.
Mixing ratio
3:1 ratio, Part A: Part B by volume.
Fast cure option
The Bolt Part B Hardener may be used with Universal Part A which will significantly reduce the cure time.
Cure times @25°C using the Bolt Part B Hardener
| Pot life | 15 minutes |
|---|---|
| Tack free time | 2 – 3 hours (approximately) |
| Re-coat time | 3 – 24 hours (approximately) |
| Cure time — 6 Hours | Light foot traffic |
| Cure time — 24 Hours | Light mechanical traffic |
| Cure time — 7 Days | Full cure |
| Application Temperature | 10°C – 30°C |
| Mixing ratio using Bolt hardener | 3:1 – Part A : Part B by volume |
Packaging
- 20L Pre tinted Kit – Part A 15L + Part B 5L
- 6L Pre-tinted kit – Part A 4.5L + Part B 1.5L
Consumption rates
6 – 8m² /L.
Safety precautions
Wear appropriate personal protection equipment. Gloves, eye protection, mask and overalls should be used during mixing and application.
Shelf life
12 months from date of manufacture, stored under shelter at 25⁰C in the original un-opened container.
Colour
Hychem Universal is an industrial flooring finish which may discolour on exposure to on exposure to UV light from the sun or an artifical source. The severity of discolouration is dependant on colour choice. Any such discolouration has no effect on the performance of the product.
Technical data
| Property | Value | Unit / method |
|---|---|---|
| Test conditions | @ 25°C – (Standard Hardener) | |
| Pot Life | 45 | minutes |
| Tack Free time | 8 | hours |
| Recoat time | 8 – 24 | hours |
| Application temperature | 10°C – 30°C | |
| Cure time | 24 hours – foot traffic 3 days – light mechanical traffic 7 days – full cure | |
| Hardness Shore D – 7 days | 78 | |
| Compressive strength | 75 | MPa |
| Available Colours | Neutral Grey AS N23, Light Grey AS N35, Koala Grey, N45 Bridge Grey N44, Dark Grey AS N64 other colours can be made to order and require a minimum order of 30+ kits. |
Chemical resistance
Different epoxy products vary in their resistance to chemicals. Always ensure that the correct product is chosen for the service environment to be encountered. If in doubt contact your Hychem representative or the Hychem technical department for advice. Chemical spillage of acids and sanitizing agents may attack the pigments used in the coating and result in discolouration.
Questions about Hychem Universal
Where is Hychem Universal used?
Hychem Universal is used for: Hychem Universal is recommended for use as a coloured, heavy-duty floor coating for commercial, industrial and residential applications.; Garages; Warehouses; Schools, hospitals and public buildings; Prisons; Retail areas. See Aircraft hangar flooring, Automotive workshop flooring, School and university flooring.
How long does Hychem Universal take to cure?
Tack Free time: 8 hours. Recoat time: 8 – 24 hours. Cure time: 24 hours – foot traffic 3 days – light mechanical traffic 7 days – full cure. Lower temperatures extend these times; the data sheet gives the conditions.
Where is the Hychem Universal data sheet?
Download the Hychem Universal technical data sheet (PDF). For the safety data sheet, request it and we send it the same day.
Who installs Hychem Universal?
Hychem Universal is supplied by Hychem and laid by an approved applicator from our national network — jobs of any size, in every state. How supply and installation works.
Similar systems
Other Concrete Sealers and Coatings systems for automotive workshops.
- Hychem PU200Two pack non-yellowing polyurethane floor finishView system Data sheetChemical resistantSlip resistantUV stable
- Hychem PA315High gloss, pigmented polyasparticView system Data sheetChemical resistantFast cureGreen Star
- Hychem SupaFloorMulti-Purpose Pigmented Epoxy Flooring SystemView system Data sheetChemical resistant