Hychem SupaFloor SL — 100% solids, high gloss, high build, pigmented epoxy for application thicknesses 2mm – 5mm
Product description
HYCHEM Supafloor SL is a 100% solids, high gloss, ultra-smooth, pigmented epoxy flooring resin. Hychem Supafloor SL can be used as a standalone coating or as part of a Hychem specified system for specific performance requirements.
Typical applications
- Aviation hangars and maintenance facilities
- Motor workshops
- Public buildings e.g. schools and hospitals
- Prisons
- Plant rooms
- Factories
- Warehouses
- Film studios
- Food and beverage processing areas
- Retail areas
- Pharmaceutical and laboratories
- Abattoirs
Features and benefits
- Slip resistant with the addition of textured aggregates
- Self-smoothing
- Seamless
- Abrasion and impact resistant
- High mechanical strength
- Excellent resistance to early water spotting
- Jet fuel resistant
- High resistance to aviation hydraulic fluids e.g. Skydrol, HyJet etc.
- High resistance to battery acid and caustic compounds
- High resistance to commercial cleaners, detergents, degreasers, organic solvents, lubricating and de-icing fluids etc.
Approvals and certifications
- Version 1.2: 2017 (Emission testing method CA 01350)
- VOC ASTM D2369-10
- VOC ASTM D3960
- APAS-S0209/1L V3 (Class I)
- Green Star Interiors V1.3-12.1.B — Green Star & As Built
- Green Star Interiors V1.3-13.1.B — Green Building Council of Australia
- HACCP Certified
- CRF Compliant
Application guidelines
Summary from the data sheet — follow the PDF on site.
Surface preparation
Prior to the application of HYCHEM Supafloor SL, the substrate must be thoroughly prepared.
- The substrate must be clean and firm with a minimum compressive strength of 25MPa and a minimum surface tensile strength of 1.5MPa.
- The moisture content of the concrete must be below 5%.
- New concrete must be allowed to cure for minimum 28 days.
- In most instances, mechanical preparation is required.
- All dust, loose and friable material must be completely removed from all surfaces before application, preferably by vacuum.
Pre-conditioning product
It is important to note that even when the application environment is warm, products which have been stored in cold or cooler conditions should be pre-conditioned, ideally to 20-25°C, to ease mixing and application and help avoid other potential issues such as amine bloom or blushing. Applying a cold product in a warm environment is not recommended.
Mixing (self-smoothing)
Mix Part A resin, Part B hardener and the pigment together for 1 minute before adding all or part of the ESL fillers supplied depending on the application temperature and the thickness required. Continue mixing slowly to minimise air for a further 2 minutes until a uniform consistency is achieved. Where multiple mixes are required, each mix should be timed so no variations exist.
Application (self-smoothing)
Pour the mix onto the primed substrate and spread with a flat or notched trowel or pin rake. Ensure the material is spread evenly and to the required thickness. Roll with a spiked roller to eliminate air bubbles. NB. overly porous substrates may require double priming.
Mixing (heavy duty slip resistant topping)
Mix Part A resin, Part B hardener and the pigment together for 1 minute before adding all or part of the ESL fillers supplied depending on the application temperature and the thickness required. Continue mixing slowly for a further 2 minutes until a uniform consistency is achieved.
Application (heavy duty slip resistant topping)
Pour the mix onto the primed and fully sealed substrate and spread with a flat or notched trowel or pin rake. Roll with a spiked roller to eliminate air bubbles. For sloping floors, additional aggregate may be required to reduce flow. Broadcast selected aggregate to refusal into the un-cured material. Allow to cure, vacuum off loose aggregate, then apply selected HYCHEM top coat.
Application information
| Mix Ratio (Part A to Part B) | 2.85 : 1 by volume (plus filler) |
|---|---|
| Application Temperature | 8 °C to 35 °C |
| Relative Air Humidity | < 75 % RH |
| Pot Life / Working Time @ 23°C | approx. 15 minutes (less in large volume) |
| Tack Free Time @ 23°C | 4 – 5 hours |
| Recoat Window (minimum – maximum) | 5 – 24 hours |
| Packaging — 13.5L kit | 9L Part A + 1L pigment + 3.5L Part B |
| Packaging — 14L pre-tinted | 10L Part A + 3.5L Part B |
| Example of Yield Per Kit with Filler | 13.5L SL + 12.5kg silica flour = approx. 17.5L |
| Consumption (trowel) | 2 – 5L/sqm |
| Cure Time – Pedestrian | 24 hours |
| Cure Time – Mechanical | 48 hours |
| Cure Time – Full Chemical | 7 days |
Environmental conditions
Temperature and the surrounding atmospheric conditions will play a part in the curing process of all resin products. Under conditions of low temperatures and high humidity the final cured surface finish can be adversely affected, potentially resulting in poor gloss retention, discoloration over time, poor overcoat ability and inter-coat adhesion. Quite often these conditions will result in the formation of a white film over the surface, often evident after contact with water. If this occurs, the existing coating will need to be abraded to completely remove the affected surface to ensure the adhesion of subsequent applications. In some cases, partial or complete re-priming may be necessary. Attention also needs to be paid to the substrate temperature, which should be at least 3-5 °C above the dew point during the curing phase. Industry standards recommend the accurate recording of environmental conditions such as substrate and air temperatures, humidity levels and dew point readings during both the application and curing processes. Full material warranties cannot be provided unless all the relevant data has been recorded accurately. If in doubt consult the HYCHEM technical department for advice.
Safety precautions
Wear appropriate personal protection equipment. Gloves, eye protection, mask and overalls should be used during mixing and application.
Shelf life
Minimum 12 months from date of manufacture when stored under shelter at 25°C in the original un-opened container.
Storage conditions
The packaging must be stored properly in original, unopened and undamaged sealed packaging, in dry conditions at temperatures between 5°C and 30°C.
Colour
HYCHEM Supafloor SL is supplied with pigment. As with most epoxy finishes, surface yellowing may occur on exposure to UV light from the sun or an artificial source. Any such discolouration has no effect on the performance of the product.
Important considerations
- Coatings and overlays containing water must not be applied directly to HYCHEM Supafloor SL resin unless a sufficiently porous mortar has been installed or it has been fully broadcast with dry aggregate e.g. quartz or silica sand.
- Ensure consumption of material is uniform to achieve proper appearance, texture and consistent performance.
- Ensure the material is mixed and stirred properly. Incorrect mixing can lead to performance issues.
- If heating is required do not use gas, oil, paraffin or other fossil-fuel heaters. Use only electric-powered warm-air blower systems.
- At low temperatures and low humidities (< 40% relative humidity), curing and recoat times will be affected.
Technical data
| Property | Value | Unit / method |
|---|---|---|
| Composition | Epoxy (2-part solvent-free) | |
| Colour | Pigmented – Use Hychem Epoxy Pigments | |
| Solids Content | 100 | % |
| Gloss Level | Gloss | |
| VOC Content | 31 | g/L |
| Service Temperature | Up to 65 °C |
From the technical data sheet, updated .
Physical properties
| Property | Value | Unit / method |
|---|---|---|
| Hardness Shore D – 7 Days | 78 | |
| Compressive Strength | 95 | MPa |
| Scratch Resistance | Excellent |
From the technical data sheet, updated .
Chemical resistance
HYCHEM Supafloor SL is resistant to jet fuel, aviation hydraulic system fluids, battery acids and caustic compounds, cleaners, detergents, degreasers, organic solvents and lubricating and de-icing fluids. Different epoxy products vary in their resistance to chemicals. Always ensure that the correct product is chosen for the service environment. If in doubt contact your HYCHEM representative or the HYCHEM technical department for advice.
Questions about Hychem SupaFloor SL
Where is Hychem SupaFloor SL used?
Hychem SupaFloor SL is used for: Aviation hangars and maintenance facilities; Motor workshops; Public buildings e.g. schools and hospitals; Prisons; Plant rooms; Factories.
How thick is Hychem SupaFloor SL applied?
Hychem SupaFloor SL: 100% solids, high gloss, high build, pigmented epoxy for application thicknesses 2mm – 5mm. The data sheet gives the coverage for each thickness.
Which standards and approvals does Hychem SupaFloor SL meet?
Version 1.2: 2017 (Emission testing method CA 01350); VOC ASTM D2369-10; VOC ASTM D3960; APAS-S0209/1L V3 (Class I); Green Star Interiors V1.3-12.1.B — Green Star & As Built.
Where is the Hychem SupaFloor SL data sheet?
Download the Hychem SupaFloor SL technical data sheet (PDF), edition 27 July 2026. For the safety data sheet, request it and we send it the same day.
Who installs Hychem SupaFloor SL?
Hychem SupaFloor SL is supplied by Hychem and laid by an approved applicator from our national network — jobs of any size, in every state. How supply and installation works.
Similar systems
Other Heavy Duty Industrial Solutions systems.
- Hychem Aero-Tuff RapidEpoxy and polyaspartic floor system for hangars, UV stableView system Data sheetChemical resistantGreen StarSlip resistant
- Hychem Hycrete TCTopcoat for polyurethane concreteView system Data sheetChemical resistantLow temperature cureLow VOC
- Hychem SupaFloor “Premium” coating @ 1mm+ (heavy-duty)Heavy-duty epoxy floor coating system, 1 mmView system Data sheetSlip resistant