Coolroom and freezer flooring
For coolrooms, freezers and cold stores, specify polyurethane cement. Hychem Hycrete lists cold storage warehouses, coolrooms and freezers among its applications: it takes forklifts, moisture and washdown, and an accelerator lets it cure at low temperatures. Its seal coat, Hycrete TC, is rated from −20 °C to 120 °C.
What the floor has to handle
- Temperature
- chilled rooms and freezers; Hycrete TC is rated −20 °C to 120 °C
- Traffic
- forklifts and pallet jacks on a floor that never warms up
- Moisture
- condensation and washdown
- Downtime
- rooms that cannot be warmed or emptied for long
- Heavy Duty Industrial SolutionsHychem Hycrete PU-SLPolyurethane concrete flooring systemView system Data sheetFast cureFood safeSlip resistant
- Heavy Duty Industrial SolutionsHychem Hycrete TCTopcoat for polyurethane concreteView system Data sheetChemical resistantLow temperature cureLow VOC
- Concrete Sealers and CoatingsHychem E100Solvent-based, two-component epoxy primer for concreteView system Data sheet
- Concrete Sealers and CoatingsHychem SF20Heavy duty epoxy coating with good colour stabilityView system Data sheetChemical resistantSlip resistant
Also suits every industry
Standards that apply
| Standard | Title | What it means for the floor |
|---|---|---|
| FSANZ Standard 3.2.3 | Food Premises and Equipment (Food Standards Code) | Floors must be able to be effectively cleaned, must not absorb grease, food particles or water, and must be laid so water does not pool. |
| AS 4586-2013 | Slip resistance classification of new pedestrian surface materials | Classes a new floor: P0–P5 on the wet pendulum, R9–R13 on the oil-wet ramp, A–C for wet barefoot areas. Ask for the class the area needs, not just "non-slip". |
Which product holds which certificate: certifications and approvals.
FAQs about coolroom and freezer flooring
What temperatures can the floor take?
Hycrete TC, the seal coat, is rated from −20 °C to 120 °C. For blast freezers colder than −20 °C, ask us before you specify.
Can it be laid in a cold room?
Hycrete PU-SL is available with a chemical accelerator for fast cure at low temperatures. Polyac MMA can be laid below freezing where a room cannot be warmed.
Why not a standard epoxy?
Cold stores see condensation, washdown and constant forklift traffic on a cold slab. Polyurethane cement is made for that service; standard epoxies cure slowly in the cold.
Specification service
Specifying for this environment?
Tell us the temperatures, the traffic and when the room can come off line.
or call 1300 HYCHEM



